home » products » Standard products & systems » dc power supplies  
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Power Supplies

Variable DC - Regulated Linear Power Supplies
Specifications :
OUTPUT VOLTAGE
30 V
30 V dual
30 V
30 V
30 V
ADJUSTABILITY
0-30 V
0-30 V
0-30 V
0-30 V
0-30 V
OUT PUT CURRENT
1 or  2 A
1 & 2 A
5 A
10 A
30 A
CURRENT ADJUST
0-1 or 2A
0-2 A
0-5 A
0-10 A
0-30 A
CURRENT LIMIT
1.2  to 1.4A
1.2  to 1.4A
5.2 to 5.4A
10.2 to 10.4A
30.2 to 30.4A
2.2  to 2.4A
2.2 to 2.4A

-

-
-
SHORTCIRCUIT PROTECTION
Provided
3 1/2 DIGIT PANEL METER FOR VOLTS & CURRENT
Provided
VOLT METER ACCURACY
0.5% FSR
0.5% FSR
0.5% FSR
0.5% FSR
0.5% FSR
CURRENT METER ACCURECY
1% FSR
1% FSR
1% FSR
1% FSR
1% FSR
LOAD REGULATION
0.1%.
0.1%.
0.1%.
0.1%.
0.1%.
LINE REGULATION
0.1%.
0.1%.
0.1%.
0.1%.
0.1%.
RIPPLE (NOISE)
<10 mVpp
<10 mVpp
<10 mVpp
<10 mVpp
<10 mVpp
CV, CC INDICATIONS
Provided
TRACKING
-
Provided
-
-
-
TRACKING ACCURACY
-
1%.
-
-
-
INPUT VOLTAGE
230 Vac, 50Hz
230 Vac, 50Hz
230 Vac, 50Hz
230 Vac, 50Hz
230 Vac, 50Hz
Variable High Voltage DC - Regulated Linear Power Supplies
Specifications :
OUTPUT VOLTAGE
120 V
120 V
300 V
300 V
ADJUSTABILITY
0-120 V
0-120 V
0-300 V
0-300 V
OUT PUT CURRENT
2 A
10 A
1 A
2 A
CURRENT ADJUST
0-2A
0-10 A
0-1 A
0-2 A
CURRENT LIMIT
2.2  to 2.3A
10 to 10.3A
1.2 to 1.35A
2.2 to 2.3A
SHORTCIRCUIT PROTECTION
Provided
Over Load Protection
3 1/2 DIGIT PANEL METER FOR VOLTS & CURRENT
Provided
VOLT METER ACCURACY
0.5% FSR
0.5% FSR
0.5% FSR
0.5% FSR
CURRENT METER ACCURECY
1% FSR
1% FSR
1% FSR
1% FSR
LOAD REGULATION
0.1%.
0.1%.
0.1%.
0.1%.
LINE REGULATION
0.1%.
0.1%.
0.1%.
0.1%.
RIPPLE (NOISE)
<10 mVpp
<10 mVpp
<10 mVpp
<10 mVpp
CV, CC INDICATIONS
Provided
TRACKING
-
TRACKING ACCURACY
-
INPUT VOLTAGE
230 Vac, 50Hz
230 Vac, 50Hz
230 Vac, 50Hz
230 Vac, 50Hz
Preset DC - Regulated Linear Power Supplies
Specifications :
OUTPUT VOLTAGE
± 12V
5 V
60 V
60 V
ADJUSTABILITY
10.5-15.5 V
4.75-5.5 V
0-60 V
0-60 V
OUT PUT CURRENT
1 or 2 A
1 & 2 A
5 A
10 A
CURRENT ADJUST
1 & 2A
5 A
2 A
5 & 10 A
CURRENT LIMIT

-

-

0 to 2 A
0 to 5 A
SHORTCIRCUIT PROTECTION
Provided
3 1/2 DIGIT PANEL METER FOR VOLTS & CURRENT
-
-
Provided
VOLT METER ACCURACY
-
-
0.5% FSR
0.5% FSR
CURRENT METER ACCURECY
-
-
1% FSR
1% FSR
LOAD REGULATION
0.1%.
0.1%.
0.1%.
0.1%.
LINE REGULATION
0.1%.
0.1%.
0.1%.
0.1%.
RIPPLE (NOISE)
<10 mVpp
<10 mVpp
<10 mVpp
<10 mVpp
CV, CC INDICATIONS
O/P Indication
Provided
TRACKING
-
TRACKING ACCURACY
-
INPUT VOLTAGE
230 Vac, 50Hz
230 Vac, 50Hz
230 Vac, 50Hz
230 Vac, 50Hz